Energy Saving:
Energy saving is mainly manifested in the application of fan and water pump. While the fan, or pump type load adopts frequency conversion speed regulation, power saving rate will be 20% ~ 60%, this is because the actual power consumption of fan, pump type load is basically proportional to the third square of speed. When the average flow required by users is small, fans and pumps will use frequency control to reduce their speed, so energy saving effect is very obvious. But the traditional fan and pump uses baffle and valve to adjust the flow, so the motor speed is basically unchanged as well as the power consumption. According to statistics, fan and pump type motor power consumption is of 31% of the country’s power consumption, industrial power consumption is of 50%. It is very important to use variable frequency speed-regulating device on this kind of load. At present, the successful application involves constant pressure water supply, all kinds of fans, central air conditioning and hydraulic pump frequency control.
Technical Specification:
- Maximum Frequency Vector Control:0~500Hz, V/F Control:0~500Hz
- Switching Frequency0.5kHz~16kHz;
The switching frequency will be automatically adjusted according to the load characteristics. - Input Frequency Resolution Digital Setting: 0.1Hz
Analog Setting: 0.01V corresponding maximum frequency ×0.1% - Control Mode Open Loop Vector Control (SVC, V/F Control
- Start Torque G Type:0.5Hz/150%(SVC), P Type:0.5Hz/100%
- Speed Range and Precision1:100(SVC)±0.5%(SVC)
- Over Load Capability G Type:150% rated current 60s ;180% rated current 3s, P Type:120% rated current 60s ;150% rated current 3s
- Torque Boost: 0.1%~30.0%
- V/F Curve Line Type, Square Type
- Acc. / dec. Curve straight line or S curve acceleration and deceleration mode. Acceleration and deceleration time range between 0.0 to 500.0s.
- DC Braking DC Braking Frequency:0.00Hz to maximum frequency. Braking time: 0.0s to 36.0s
- Multi-speed Running It can realize at maximum of 4 segments speed running via the control terminal. Built-in PID It is easy to realize process-controlled closed loop control system., Over-voltage/current Stall Control It can limit the running voltage/current automatically and prevent frequent over voltage/current tripping during the running process.
- Motor Over-temperature Protection: Acceptable motor temperature sensor input (PT100, PT1000)
- Timer Control: Timer control function: set time range 0.0~6500.0Min
- Communication: Modbus
- Protection Function: It can implement power-on motor short-circuit detection, output phase loss protection, over current protection, over voltage protection, under voltage protection, overheating protection and overload protection, which can be turned on or shielded as required.
- Installation Conditions Indoor, and be free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.
- Altitude0~4000m;Derating use when more than 1000m (decrease by 1% per 100 meters)
- Ambient Temperature-10 ℃ to +40 ℃ (Derating use when under ambient temperature of 40 ℃ to 50 ℃)
- Humidity Less than 95%RH, without condensing
- Vibration Less than 5.9m/s (0.6g)
- Storage Temperature-20℃~+60℃
- IP Level IP20
- Pollution Level PD2
- Power Distribution System: TN , TT